AC Output
115V/15A AC sockets for compatible equipment within the inverter rating.










Free US shipping. Sales tax calculated at checkout.

Convert 12V battery power into 115V AC modified sine wave output with 1000W continuous power. Compact 12V-to-AC power with essential AC and USB connections.
Monitor connected-battery level, AC output power, input voltage and fault messages directly on the inverter display.

Confirm every connected device supports modified sine wave power and remains within the inverter ratings.
115V/15A AC sockets for compatible equipment within the inverter rating.
USB-A and USB-C provide 5V DC, 3.1A shared output.
The specification table lists three 40A fuses for TANK1000.
The inverter monitors battery voltage, internal temperature, output demand and short-circuit conditions.

Provides warning before shutdown.
Shuts down under low-input conditions.
Protects against excessive battery input voltage.
Model-specific information transcribed from the TANK Series user guide.
| Model | ERAYAK TANK1000 |
|---|---|
| Continuous Power | 1000W |
| Surge Power | 2000W |
| Input | 12V battery system |
| Nominal Output | 115V AC |
| Waveform | Modified sine wave |
| No-Load Draw | <0.45A DC |
| USB | 5V DC, 3.1A shared |
| AC Connections | 115V/15A AC sockets |
| Remote On/Off | Not Included |
| Fuse | 40A×3 |
| Cooling | Temperature-controlled fan |
| Protection | Low/high voltage, over-temperature, overload and short circuit |
| Weight | 2.1 lb / 1.0 kg |
High-current inverter performance depends on correct battery condition, cable connection, ventilation and load management.
Key checks before installation and operation.
No. The user guide specifies modified sine wave output. Confirm connected-equipment compatibility before use.
1000W is the continuous rating and 2000W is the surge rating published in the manual. Connected equipment must stay within both limits.
The LCD shows connected-battery level, AC output power in watts, battery input voltage and fault or warning messages.
No remote switch is listed in the TANK1000 package contents or feature diagram.
The inverter displays a fault indication and shuts down under the listed abnormal conditions. Follow the reset procedure in the user guide after correcting the cause.
No. The manual states that the product is not certified for life-support or medical devices.
For product information and support, use the contact address listed in the manual.
| Warranty & Support | Coverage Details |
|---|---|
| Warranty Duration | 1-Year Limited Warranty for eligible ERAYAK TANK1000 purchases, subject to applicable warranty terms, proof of purchase, product condition, and technical verification. |
| Warranty Coverage | Coverage applies to eligible manufacturing defects and product malfunctions that occur under normal use during the applicable warranty period. |
| Technical Diagnosis | ERAYAK Technical Support may assist with troubleshooting issues such as no power output, low-voltage shutdown, high-voltage shutdown, overload or short-circuit shutdown, over-temperature protection, cooling-fan issues, fuse failure, and battery-connection problems before confirming the appropriate warranty solution. |
| Replacement Parts Support | For eligible warranty issues, ERAYAK may provide applicable replacement parts, troubleshooting assistance, or other appropriate service solutions after technical verification and warranty review. |
| Fuse Support | The TANK1000 uses replaceable fuses. ERAYAK Support can assist with fuse identification, replacement guidance, and troubleshooting when a fuse-related issue occurs. |
| Battery Connection Support | Support is available for the threaded positive (+) and negative (-) terminals, terminal input cables, 12V battery connection, and related input-power troubleshooting. |
| Technical Support | ERAYAK provides assistance with product setup, 12V battery connection, load planning, modified sine wave compatibility, LCD monitoring, fault diagnosis, fuse questions, ventilation guidance, and after-sales support for the TANK1000. |
| Email Support | support@erayakpower.com Customers may submit proof of purchase, order information, photos, videos, product details, and a description of the issue for technical review. |
| English Phone Support | +1 (573) 455-4565 English-speaking support is available for setup, troubleshooting, warranty questions, replacement-part assistance, and after-sales service. |
| WhatsApp Support | +1 (573) 455-4565 Contact ERAYAK via WhatsApp for convenient technical and after-sales assistance. |
| Warranty Claim Process | Contact ERAYAK Support with your proof of purchase, product model, order information, and a description of the issue. Photos, videos, battery information, connected-device details, or troubleshooting results may be requested before the appropriate warranty solution is confirmed. |
| Proper Use Requirement | Warranty service is subject to proper operation with a compatible 12V battery, correct polarity, adequate ventilation, appropriate connected loads, and operation within the TANK1000's 1000W continuous / 2000W surge output limits. |
| Service & Repair | Do not perform unauthorized internal repairs or modifications. If the inverter, cables, terminals, cooling fan, housing, or electrical connections show serious damage, discontinue use and contact ERAYAK Support or qualified service personnel. |
Warranty Note: Warranty service is subject to the applicable ERAYAK warranty terms, proof of purchase, proper operation and maintenance, technical verification, and applicable exclusions. Misuse, incorrect polarity, excessive load, blocked ventilation, moisture exposure, unauthorized modification or repair, physical damage, or other operation outside the TANK1000 user guide may affect warranty eligibility.
| U.S. Shipping | Details |
|---|---|
| U.S. Warehouses | ERAYAK provides local U.S. fulfillment from warehouses in California, New Jersey, and Georgia. |
| Order Processing | Most orders are confirmed and prepared for shipment within 24 hours after order verification. |
| Tracking Number | A tracking number is provided after the order is shipped so customers can follow the delivery status online. |
| Standard Delivery | Most standard orders are estimated to arrive within 2–4 business days after shipment. |
| Expedited Processing | Expedited service is available for eligible orders. Expedited orders receive priority order confirmation, faster warehouse processing, and priority logistics handling. |
| 2-Business-Day Delivery Option | A 2-business-day delivery option may be available for eligible products and destinations. Availability and any additional shipping charges should be confirmed before ordering. |
| Shipping Coverage | Delivery is available across most locations within the contiguous United States. |
| Hawaii & Offshore Areas | For Hawaii, U.S. islands, offshore territories, or other locations outside the contiguous United States, please contact ERAYAK Support before placing your order to confirm shipping availability and cost. |
| Warehouse Assignment | Orders are fulfilled from the most suitable U.S. warehouse based on product availability and the customer's delivery location. |
| Shipping Support | Email: support@erayakpower.com Phone: +1 (573) 455-4565 WhatsApp: +1 (573) 455-4565 |
Shipping Note: Delivery times are estimates and may vary based on inventory availability, destination, carrier conditions, weather, holidays, and other logistics factors. For urgent, remote-area, or special delivery requests, contact ERAYAK Support before placing your order.
| Specification | Details |
|---|---|
| Model | ERAYAK TANK1000 |
| Product Type | 1000W Power Inverter |
| Continuous Power | 1000W |
| Surge Power | 2000W |
| Compatible Power Source | 12V Battery |
| Nominal AC Output Voltage | 115V AC |
| AC Output Waveform | Modified Sine Wave |
| AC Outlets | 115V / 15A AC Sockets |
| USB Ports | USB-A + USB-C |
| USB Output | 5V DC, 3.1A Shared |
| No-Load Power Draw | <0.45A DC |
| LCD Display | Yes |
| Battery Level Indicator | Yes |
| Output Power / Input Voltage Display | Yes |
| Fault Indicator | Yes |
| Low Battery Alarm | 10.5V DC |
| Low Battery Shutdown | 9.5V DC |
| High Battery Voltage Shutdown | 15.5V DC |
| Over-Temperature Protection | Yes |
| Cooling Fan | Yes — Temperature-Controlled |
| Overload & Short-Circuit Protection | Yes |
| Fuses | 3 × 40A |
| Battery Connection | Threaded Positive (+) / Negative (-) Terminals with Terminal Input Cables |
| Dimensions | 7.3 × 4.2 × 1.1 in |
| Weight | 2.1 lb / 1.0 kg |
| Package Contents | 1 × TANK1000 Inverter, 1 Pair × Terminal Input Cables, 1 Set × Fuses, 1 × Product Brochure |
Performance Note: Actual operation depends on battery condition, connected load, startup surge, temperature, ventilation, and device compatibility. The TANK1000 produces modified sine wave AC output, so always verify the connected device's voltage, wattage, startup surge, and waveform requirements before use.
The TANK1000 provides up to 1000W of continuous AC power and 2000W of surge capacity for compatible 12V battery-powered applications.
With a no-load power draw of less than 0.45A DC, the TANK1000 helps limit unnecessary battery consumption when the inverter is powered on without a significant connected AC load.
The LCD display lets you monitor battery input voltage and battery level, helping you better manage available battery power during use.
A low-battery alarm activates at 10.5V DC, while low-battery shutdown occurs at 9.5V DC to help reduce excessive battery discharge.
The user guide recommends disconnecting the inverter when it is not in use to help prevent accidental battery discharge. The USB ports remain active even when the inverter is switched off.
The TANK1000 provides a low-battery alarm at 10.5V DC and shuts down at 9.5V DC to help protect the connected battery from excessive discharge.
The inverter shuts down if battery voltage rises above its safe operating range. The specified high-voltage shutdown point is 15.5V DC.
The TANK1000 monitors operating temperature and shuts down if the internal temperature exceeds the safety threshold.
The built-in temperature-controlled cooling fan operates as needed to support stable performance and help manage heat under load.
The inverter shuts down when connected power demand exceeds the rated 1000W output or when a short circuit is detected.
Three 40A fuses provide additional electrical protection for the TANK1000 power system.
The LCD display can show fault information and warning messages, helping users identify abnormal operating conditions and take corrective action.
| Compatibility | Typical Equipment | Compatibility Details |
|---|---|---|
| 12V Battery Systems | Compatible 12V vehicle, RV, marine, or standalone battery systems | The TANK1000 is designed to connect directly to a compatible 12V battery using the supplied terminal input cables. Always observe correct battery polarity. |
| Laptops & Chargers | Laptop adapters, chargers, and compatible AC-powered electronics | Suitable for compatible equipment when the total connected load remains within the TANK1000's 1000W continuous rating and the equipment supports modified sine wave power. |
| Phones & Tablets | Smartphones, tablets, and compatible portable electronics | USB-A and USB-C provide 5V DC output with up to 3.1A shared current for compatible USB devices. |
| Small Appliances | Compatible low-to-medium power household or travel appliances | Appliances may be used when their running wattage and startup surge remain within the TANK1000's 1000W continuous / 2000W surge capacity. |
| Multiple Devices | AC and USB-powered electronics used together | Multiple compatible devices may be connected at the same time as long as the combined continuous demand remains within 1000W. |
| High-Starting-Surge Devices | Devices with motors, compressors, or significant startup demand | The startup surge must remain within the TANK1000's 2000W surge capacity. Always check the equipment manufacturer's requirements before use. |
| Modified Sine Wave Equipment | Compatible AC-powered equipment designed to operate with modified sine wave power | The TANK1000 produces modified sine wave AC output. Confirm compatibility before connecting equipment that requires pure sine wave or another specific waveform. |
| Battery Monitoring Applications | Vehicle, RV, mobile-work, and off-grid battery-powered setups | The LCD display shows battery level and can switch between AC output power and battery input voltage for real-time monitoring. |
| High-Power Appliances | Heaters, kettles, microwave ovens, cooking appliances, and other high-wattage devices | Use only when the appliance's continuous and startup demand remain within the TANK1000's 1000W continuous / 2000W surge limits. Many high-power appliances may exceed these limits. |
| Medical & Life-Support Equipment | Life-support systems and medical devices | Not intended for use. The user guide states that the inverter is not certified for use with life-support or medical devices. |
Important Compatibility Note: The ERAYAK TANK1000 provides up to 1000W continuous power / 2000W surge power from a compatible 12V battery. It produces modified sine wave AC output. Always verify connected-device voltage, running wattage, startup surge, and waveform requirements before use.
Keeping your ERAYAK TANK1000 in good operating condition is straightforward. Routine maintenance mainly involves checking the battery connections, monitoring battery voltage and connected load, keeping the cooling system clear, and inspecting the terminal cables and fuses when needed.
| Maintenance Item | When to Check | What to Do |
|---|---|---|
| Battery Connections | Before each use | Check the positive (+) and negative (-) threaded terminals and terminal input cables for secure connection, wear, or visible damage. |
| Battery Voltage | Before and during use | Monitor battery condition using the LCD display and respond to low- or high-voltage warnings when they occur. |
| Connected Load | Before and during use | Keep total continuous demand within 1000W and startup surge within 2000W. |
| Cooling Fan & Ventilation | During use | Keep the cooling fan and ventilation openings unobstructed and maintain at least 3 inches of clearance around the inverter. |
| Fuses | If power is lost or a protection issue occurs | Inspect the TANK1000's 3 × 40A fuses and replace only with the correct type and rating when necessary. |
| LCD & Fault Indicators | During use | Monitor battery level, power output, voltage, and fault messages for signs of abnormal operation. |
| Physical Condition | Before use | Inspect the housing, terminal cables, terminals, fan, and connections for visible damage. |
| Storage | When not in use | Disconnect the inverter from the battery and store it in a dry indoor area away from direct sunlight, heat, moisture, and conductive dust. |
Service Note: The TANK1000 does not require engine-style scheduled maintenance. Regular inspection of battery connections, fuses, ventilation, connected load, and physical condition is the primary maintenance requirement.
Inspect the terminal input cables and threaded positive (+) and negative (-) terminals before use. Make sure all connections are secure and correctly polarized before turning on the inverter.
The TANK1000 provides a low-battery alarm at 10.5V DC and shuts down at 9.5V DC.
If a low-voltage shutdown occurs, recharge or replace the battery and make sure the inverter is connected to a fully charged compatible 12V battery.
The inverter also provides high-voltage shutdown at 15.5V DC. Disconnect any charging source that causes battery voltage to exceed the safe operating range.
The TANK1000 provides 1000W continuous power and up to 2000W surge power.
If an overload or short-circuit shutdown occurs, disconnect high-power devices and verify that the total continuous load remains within 1000W.
Do not cover or block ventilation openings. Allow at least 3 inches (7.5 cm) of clearance around the TANK1000 for proper airflow.
If an over-temperature shutdown occurs, turn off connected devices and allow the inverter to cool for at least 10 minutes. Make sure the cooling fan is not blocked and that air can circulate freely before restarting.
The TANK1000 uses 3 × 40A fuses. If a fuse-related problem is suspected, disconnect the inverter from the battery before inspection or replacement.
Replace fuses only with the correct type and rating specified for the TANK1000.
Disconnect the TANK1000 from the battery when it is not in use to help prevent accidental battery discharge.
The user guide notes that the USB ports remain active even when the inverter itself is switched off.
Disconnect the inverter from the battery before cleaning, inspection, or storage.
Important Reminder: Use the TANK1000 with a compatible 12V battery, keep continuous output within 1000W and surge demand within 2000W, maintain at least 3 inches of ventilation clearance, monitor battery voltage, use the specified 3 × 40A fuses, and disconnect the inverter from the battery when it is not in use.
Convert 12V battery power into 115V AC modified sine wave output with 1000W continuous power. Compact 12V-to-AC power with essential AC and USB connections.
Monitor connected-battery level, AC output power, input voltage and fault messages directly on the inverter display.

Confirm every connected device supports modified sine wave power and remains within the inverter ratings.
115V/15A AC sockets for compatible equipment within the inverter rating.
USB-A and USB-C provide 5V DC, 3.1A shared output.
The specification table lists three 40A fuses for TANK1000.
The inverter monitors battery voltage, internal temperature, output demand and short-circuit conditions.

Provides warning before shutdown.
Shuts down under low-input conditions.
Protects against excessive battery input voltage.
Model-specific information transcribed from the TANK Series user guide.
| Model | ERAYAK TANK1000 |
|---|---|
| Continuous Power | 1000W |
| Surge Power | 2000W |
| Input | 12V battery system |
| Nominal Output | 115V AC |
| Waveform | Modified sine wave |
| No-Load Draw | <0.45A DC |
| USB | 5V DC, 3.1A shared |
| AC Connections | 115V/15A AC sockets |
| Remote On/Off | Not Included |
| Fuse | 40A×3 |
| Cooling | Temperature-controlled fan |
| Protection | Low/high voltage, over-temperature, overload and short circuit |
| Weight | 2.1 lb / 1.0 kg |
High-current inverter performance depends on correct battery condition, cable connection, ventilation and load management.
Key checks before installation and operation.
No. The user guide specifies modified sine wave output. Confirm connected-equipment compatibility before use.
1000W is the continuous rating and 2000W is the surge rating published in the manual. Connected equipment must stay within both limits.
The LCD shows connected-battery level, AC output power in watts, battery input voltage and fault or warning messages.
No remote switch is listed in the TANK1000 package contents or feature diagram.
The inverter displays a fault indication and shuts down under the listed abnormal conditions. Follow the reset procedure in the user guide after correcting the cause.
No. The manual states that the product is not certified for life-support or medical devices.
For product information and support, use the contact address listed in the manual.
| Warranty & Support | Coverage Details |
|---|---|
| Warranty Duration | 1-Year Limited Warranty for eligible ERAYAK TANK1000 purchases, subject to applicable warranty terms, proof of purchase, product condition, and technical verification. |
| Warranty Coverage | Coverage applies to eligible manufacturing defects and product malfunctions that occur under normal use during the applicable warranty period. |
| Technical Diagnosis | ERAYAK Technical Support may assist with troubleshooting issues such as no power output, low-voltage shutdown, high-voltage shutdown, overload or short-circuit shutdown, over-temperature protection, cooling-fan issues, fuse failure, and battery-connection problems before confirming the appropriate warranty solution. |
| Replacement Parts Support | For eligible warranty issues, ERAYAK may provide applicable replacement parts, troubleshooting assistance, or other appropriate service solutions after technical verification and warranty review. |
| Fuse Support | The TANK1000 uses replaceable fuses. ERAYAK Support can assist with fuse identification, replacement guidance, and troubleshooting when a fuse-related issue occurs. |
| Battery Connection Support | Support is available for the threaded positive (+) and negative (-) terminals, terminal input cables, 12V battery connection, and related input-power troubleshooting. |
| Technical Support | ERAYAK provides assistance with product setup, 12V battery connection, load planning, modified sine wave compatibility, LCD monitoring, fault diagnosis, fuse questions, ventilation guidance, and after-sales support for the TANK1000. |
| Email Support | support@erayakpower.com Customers may submit proof of purchase, order information, photos, videos, product details, and a description of the issue for technical review. |
| English Phone Support | +1 (573) 455-4565 English-speaking support is available for setup, troubleshooting, warranty questions, replacement-part assistance, and after-sales service. |
| WhatsApp Support | +1 (573) 455-4565 Contact ERAYAK via WhatsApp for convenient technical and after-sales assistance. |
| Warranty Claim Process | Contact ERAYAK Support with your proof of purchase, product model, order information, and a description of the issue. Photos, videos, battery information, connected-device details, or troubleshooting results may be requested before the appropriate warranty solution is confirmed. |
| Proper Use Requirement | Warranty service is subject to proper operation with a compatible 12V battery, correct polarity, adequate ventilation, appropriate connected loads, and operation within the TANK1000's 1000W continuous / 2000W surge output limits. |
| Service & Repair | Do not perform unauthorized internal repairs or modifications. If the inverter, cables, terminals, cooling fan, housing, or electrical connections show serious damage, discontinue use and contact ERAYAK Support or qualified service personnel. |
Warranty Note: Warranty service is subject to the applicable ERAYAK warranty terms, proof of purchase, proper operation and maintenance, technical verification, and applicable exclusions. Misuse, incorrect polarity, excessive load, blocked ventilation, moisture exposure, unauthorized modification or repair, physical damage, or other operation outside the TANK1000 user guide may affect warranty eligibility.
| U.S. Shipping | Details |
|---|---|
| U.S. Warehouses | ERAYAK provides local U.S. fulfillment from warehouses in California, New Jersey, and Georgia. |
| Order Processing | Most orders are confirmed and prepared for shipment within 24 hours after order verification. |
| Tracking Number | A tracking number is provided after the order is shipped so customers can follow the delivery status online. |
| Standard Delivery | Most standard orders are estimated to arrive within 2–4 business days after shipment. |
| Expedited Processing | Expedited service is available for eligible orders. Expedited orders receive priority order confirmation, faster warehouse processing, and priority logistics handling. |
| 2-Business-Day Delivery Option | A 2-business-day delivery option may be available for eligible products and destinations. Availability and any additional shipping charges should be confirmed before ordering. |
| Shipping Coverage | Delivery is available across most locations within the contiguous United States. |
| Hawaii & Offshore Areas | For Hawaii, U.S. islands, offshore territories, or other locations outside the contiguous United States, please contact ERAYAK Support before placing your order to confirm shipping availability and cost. |
| Warehouse Assignment | Orders are fulfilled from the most suitable U.S. warehouse based on product availability and the customer's delivery location. |
| Shipping Support | Email: support@erayakpower.com Phone: +1 (573) 455-4565 WhatsApp: +1 (573) 455-4565 |
Shipping Note: Delivery times are estimates and may vary based on inventory availability, destination, carrier conditions, weather, holidays, and other logistics factors. For urgent, remote-area, or special delivery requests, contact ERAYAK Support before placing your order.
| Specification | Details |
|---|---|
| Model | ERAYAK TANK1000 |
| Product Type | 1000W Power Inverter |
| Continuous Power | 1000W |
| Surge Power | 2000W |
| Compatible Power Source | 12V Battery |
| Nominal AC Output Voltage | 115V AC |
| AC Output Waveform | Modified Sine Wave |
| AC Outlets | 115V / 15A AC Sockets |
| USB Ports | USB-A + USB-C |
| USB Output | 5V DC, 3.1A Shared |
| No-Load Power Draw | <0.45A DC |
| LCD Display | Yes |
| Battery Level Indicator | Yes |
| Output Power / Input Voltage Display | Yes |
| Fault Indicator | Yes |
| Low Battery Alarm | 10.5V DC |
| Low Battery Shutdown | 9.5V DC |
| High Battery Voltage Shutdown | 15.5V DC |
| Over-Temperature Protection | Yes |
| Cooling Fan | Yes — Temperature-Controlled |
| Overload & Short-Circuit Protection | Yes |
| Fuses | 3 × 40A |
| Battery Connection | Threaded Positive (+) / Negative (-) Terminals with Terminal Input Cables |
| Dimensions | 7.3 × 4.2 × 1.1 in |
| Weight | 2.1 lb / 1.0 kg |
| Package Contents | 1 × TANK1000 Inverter, 1 Pair × Terminal Input Cables, 1 Set × Fuses, 1 × Product Brochure |
Performance Note: Actual operation depends on battery condition, connected load, startup surge, temperature, ventilation, and device compatibility. The TANK1000 produces modified sine wave AC output, so always verify the connected device's voltage, wattage, startup surge, and waveform requirements before use.
The TANK1000 provides up to 1000W of continuous AC power and 2000W of surge capacity for compatible 12V battery-powered applications.
With a no-load power draw of less than 0.45A DC, the TANK1000 helps limit unnecessary battery consumption when the inverter is powered on without a significant connected AC load.
The LCD display lets you monitor battery input voltage and battery level, helping you better manage available battery power during use.
A low-battery alarm activates at 10.5V DC, while low-battery shutdown occurs at 9.5V DC to help reduce excessive battery discharge.
The user guide recommends disconnecting the inverter when it is not in use to help prevent accidental battery discharge. The USB ports remain active even when the inverter is switched off.
The TANK1000 provides a low-battery alarm at 10.5V DC and shuts down at 9.5V DC to help protect the connected battery from excessive discharge.
The inverter shuts down if battery voltage rises above its safe operating range. The specified high-voltage shutdown point is 15.5V DC.
The TANK1000 monitors operating temperature and shuts down if the internal temperature exceeds the safety threshold.
The built-in temperature-controlled cooling fan operates as needed to support stable performance and help manage heat under load.
The inverter shuts down when connected power demand exceeds the rated 1000W output or when a short circuit is detected.
Three 40A fuses provide additional electrical protection for the TANK1000 power system.
The LCD display can show fault information and warning messages, helping users identify abnormal operating conditions and take corrective action.
| Compatibility | Typical Equipment | Compatibility Details |
|---|---|---|
| 12V Battery Systems | Compatible 12V vehicle, RV, marine, or standalone battery systems | The TANK1000 is designed to connect directly to a compatible 12V battery using the supplied terminal input cables. Always observe correct battery polarity. |
| Laptops & Chargers | Laptop adapters, chargers, and compatible AC-powered electronics | Suitable for compatible equipment when the total connected load remains within the TANK1000's 1000W continuous rating and the equipment supports modified sine wave power. |
| Phones & Tablets | Smartphones, tablets, and compatible portable electronics | USB-A and USB-C provide 5V DC output with up to 3.1A shared current for compatible USB devices. |
| Small Appliances | Compatible low-to-medium power household or travel appliances | Appliances may be used when their running wattage and startup surge remain within the TANK1000's 1000W continuous / 2000W surge capacity. |
| Multiple Devices | AC and USB-powered electronics used together | Multiple compatible devices may be connected at the same time as long as the combined continuous demand remains within 1000W. |
| High-Starting-Surge Devices | Devices with motors, compressors, or significant startup demand | The startup surge must remain within the TANK1000's 2000W surge capacity. Always check the equipment manufacturer's requirements before use. |
| Modified Sine Wave Equipment | Compatible AC-powered equipment designed to operate with modified sine wave power | The TANK1000 produces modified sine wave AC output. Confirm compatibility before connecting equipment that requires pure sine wave or another specific waveform. |
| Battery Monitoring Applications | Vehicle, RV, mobile-work, and off-grid battery-powered setups | The LCD display shows battery level and can switch between AC output power and battery input voltage for real-time monitoring. |
| High-Power Appliances | Heaters, kettles, microwave ovens, cooking appliances, and other high-wattage devices | Use only when the appliance's continuous and startup demand remain within the TANK1000's 1000W continuous / 2000W surge limits. Many high-power appliances may exceed these limits. |
| Medical & Life-Support Equipment | Life-support systems and medical devices | Not intended for use. The user guide states that the inverter is not certified for use with life-support or medical devices. |
Important Compatibility Note: The ERAYAK TANK1000 provides up to 1000W continuous power / 2000W surge power from a compatible 12V battery. It produces modified sine wave AC output. Always verify connected-device voltage, running wattage, startup surge, and waveform requirements before use.
Keeping your ERAYAK TANK1000 in good operating condition is straightforward. Routine maintenance mainly involves checking the battery connections, monitoring battery voltage and connected load, keeping the cooling system clear, and inspecting the terminal cables and fuses when needed.
| Maintenance Item | When to Check | What to Do |
|---|---|---|
| Battery Connections | Before each use | Check the positive (+) and negative (-) threaded terminals and terminal input cables for secure connection, wear, or visible damage. |
| Battery Voltage | Before and during use | Monitor battery condition using the LCD display and respond to low- or high-voltage warnings when they occur. |
| Connected Load | Before and during use | Keep total continuous demand within 1000W and startup surge within 2000W. |
| Cooling Fan & Ventilation | During use | Keep the cooling fan and ventilation openings unobstructed and maintain at least 3 inches of clearance around the inverter. |
| Fuses | If power is lost or a protection issue occurs | Inspect the TANK1000's 3 × 40A fuses and replace only with the correct type and rating when necessary. |
| LCD & Fault Indicators | During use | Monitor battery level, power output, voltage, and fault messages for signs of abnormal operation. |
| Physical Condition | Before use | Inspect the housing, terminal cables, terminals, fan, and connections for visible damage. |
| Storage | When not in use | Disconnect the inverter from the battery and store it in a dry indoor area away from direct sunlight, heat, moisture, and conductive dust. |
Service Note: The TANK1000 does not require engine-style scheduled maintenance. Regular inspection of battery connections, fuses, ventilation, connected load, and physical condition is the primary maintenance requirement.
Inspect the terminal input cables and threaded positive (+) and negative (-) terminals before use. Make sure all connections are secure and correctly polarized before turning on the inverter.
The TANK1000 provides a low-battery alarm at 10.5V DC and shuts down at 9.5V DC.
If a low-voltage shutdown occurs, recharge or replace the battery and make sure the inverter is connected to a fully charged compatible 12V battery.
The inverter also provides high-voltage shutdown at 15.5V DC. Disconnect any charging source that causes battery voltage to exceed the safe operating range.
The TANK1000 provides 1000W continuous power and up to 2000W surge power.
If an overload or short-circuit shutdown occurs, disconnect high-power devices and verify that the total continuous load remains within 1000W.
Do not cover or block ventilation openings. Allow at least 3 inches (7.5 cm) of clearance around the TANK1000 for proper airflow.
If an over-temperature shutdown occurs, turn off connected devices and allow the inverter to cool for at least 10 minutes. Make sure the cooling fan is not blocked and that air can circulate freely before restarting.
The TANK1000 uses 3 × 40A fuses. If a fuse-related problem is suspected, disconnect the inverter from the battery before inspection or replacement.
Replace fuses only with the correct type and rating specified for the TANK1000.
Disconnect the TANK1000 from the battery when it is not in use to help prevent accidental battery discharge.
The user guide notes that the USB ports remain active even when the inverter itself is switched off.
Disconnect the inverter from the battery before cleaning, inspection, or storage.
Important Reminder: Use the TANK1000 with a compatible 12V battery, keep continuous output within 1000W and surge demand within 2000W, maintain at least 3 inches of ventilation clearance, monitor battery voltage, use the specified 3 × 40A fuses, and disconnect the inverter from the battery when it is not in use.
The TANK1000 is designed for compatible AC and USB-powered devices with a combined continuous load of up to 1000W. It can support many laptop chargers, electronics, small appliances, tools, and other compatible devices, provided their startup surge stays within the inverter’s 2000W surge capacity. Always check the device’s wattage and waveform requirements before use.
The TANK1000 provides up to 1000W of continuous power and 2000W of surge power for brief startup demand.
The TANK1000 is designed to connect directly to a compatible 12V battery using the supplied terminal input cables. Always observe correct positive and negative polarity when connecting the inverter.
The LCD display shows the connected battery level and can display AC output power in watts or battery input voltage. It also provides fault information and warning messages when abnormal operating conditions are detected.
The TANK1000 provides a low-battery alarm at 10.5V DC and shuts down at 9.5V DC. It also shuts down if battery voltage reaches 15.5V DC. These protections help protect the inverter and connected battery system.
Turn off or disconnect connected devices and allow the inverter to cool for at least 10 minutes. Make sure the cooling fan is not blocked and that there is sufficient airflow around the inverter before restarting it.
Allow at least 3 inches (7.5 cm) of clearance around the inverter during operation. Do not cover or block the ventilation openings, and do not operate the unit in a fully enclosed compartment.
Yes. The user guide recommends disconnecting the inverter when it is not in use to help prevent accidental battery discharge. The USB ports can remain active even when the inverter is switched off.