ERAYAK 9,500W Max Open-Frame Inverter Generator for Emergency Home Backup, Construction & Commercial Work, 120V/240V

Sale price$1,145.00 USD Regular price$1,199.00 USD
Questions before ordering? Call (573) 455-4565
Description
ERAYAK EYG11500iD · US Version

9,500W Max Power9,000W Rated · 120V/240V · 60Hz

An open-frame inverter generator with low-distortion output, electronic speed control and recoil + electric start. Higher-output open-frame inverter power for verified backup, workshop and commercial loads.

9,000WRated power
9,500WMaximum power
120/240VUS output
≤3%THD
4.45 hoursAt 100% load
US Output Configuration

High-Output Inverter Power

Configured for 120V/240V, 60Hz single-phase output. Verify the final US control panel and receptacles before publishing outlet-specific claims.

Core Electrical Performance

Inverter-controlled output combines electronic speed regulation with THD of 3% or lower.

120V/240VUser-confirmed US voltage configuration
60HzUS frequency selection
≤3% THDLow-distortion inverter output
12V / 8.3ADC auxiliary output
PF 1.0Single-phase power factor
LCDStandard voltage display
Fuel Capacity

25L Tank

Large tank capacity supports extended operation and reduces refueling interruptions.

Full-Load Runtime

4.45 hours

Runtime is listed at 100% load under the source-sheet test condition.

Noise Reference

76.9 dB(A)

Noise value is listed at 4 meters and 75% load in the supplied parameter sheet.

Engine & Mobility

Built Around the LY192iD Engine

Electronic speed regulation, ECO operating range and model-specific mobility hardware support transport and load-responsive operation.

459 ccEngine displacement
12kW @ 3800 rpmMaximum engine output
8.8:1Compression ratio
92 × 69 mmBore × stroke
1.1LEngine oil capacity
Recoil + electric startStarting system
3000–3800 rpmECO-mode speed range
8-inch plastic/rubber wheelsMobility configuration
Technical Specifications

EYG11500iD US Configuration

US voltage and frequency follow the user-confirmed configuration; remaining values follow the supplied model parameter sheet.

Power & Operation

  • 9,000W rated / 9,500W maximum output
  • 120V/240V, 60Hz, single-phase
  • THD ≤3%
  • 25L fuel tank
  • 4.45 hours at 100% load
  • 76.9 dB(A) at 4m / 75% load

Control & Transport

  • Inverter voltage regulation
  • Electronic speed control
  • ECO speed: 3000–3800 rpm
  • Standard speed: 3500–3800 rpm
  • 1.6Ah lead-acid battery
  • 8-inch plastic/rubber wheels
Model ERAYAK EYG11500iD · US Version
Generator Type Single-phase open-frame inverter generator
Rated / Maximum Power 9,000W / 9,500W
Voltage / Frequency 120V/240V · 60Hz
Power Factor 1.0
THD ≤3%
DC Output 12V / 8.3A
Fuel Tank 25L
Runtime 4.45 hours at 100% load
Noise 76.9 dB(A) at 4m / 75% load
Engine / Displacement LY192iD / 459 cc
Starting System Recoil + electric start
Oil Capacity 1.1L
Battery 1.6Ah lead-acid battery
Product Dimensions 650 × 542 × 560 mm
Packaging Dimensions 665 × 557 × 605 mm
Net Weight 69 kg
US panel confirmation: NEMA receptacle types, receptacle quantities, breaker ratings, neutral/ground arrangement, fuel configuration, remote-start status, CO shutoff, included accessories, certifications and warranty are not shown for the US configuration in the supplied sheet. Confirm these items before publication.

Generator Safety & Home Backup Reminder

Fuel-burning generators produce carbon monoxide and require correct outdoor placement, electrical connection and refueling practices.

  • Never run indoors.
  • Never run in a garage.
  • Never run near open windows.
  • Always operate outdoors with proper ventilation.
  • Shut down and allow the generator to cool before refueling.
  • Keep the generator dry and do not block cooling or combustion-air openings.
  • Do not connect directly to a building electrical system without code-compliant transfer equipment installed by a qualified professional.
  • Confirm connected loads match 120V/240V, 60Hz output and remain within rated and starting-power limits.
Buyer Questions

EYG11500iD FAQ

Important configuration and load questions to resolve before purchase and installation.

Is this the US electrical version?

This PDP uses the user-confirmed 120V/240V, 60Hz single-phase configuration. Verify the final control panel, labels and receptacles on the approved US production unit.

What is the difference between rated and maximum power?

9,000W is the continuous rated output and 9,500W is the published maximum output. Add simultaneous running loads and account for relevant motor or compressor startup demand.

Does ≤3% THD guarantee compatibility with every electronic device?

No. THD is one power-quality measure. Compatibility also depends on voltage, frequency, startup behavior, grounding, transient response and the connected-equipment manufacturer’s requirements.

How is the runtime measured?

The source sheet lists 4.45 hours at 100% load with a 25L tank. Actual runtime varies with load, operating mode, conditions and the final fuel configuration.

Which NEMA outlets are included?

The supplied sheet does not show the US receptacle layout. Confirm the final NEMA types, quantities, current ratings and breakers before purchase or publication.

Does this model include dual fuel, tri-fuel, remote start or CO shutoff?

The supplied sheet does not confirm these features as standard on the US SKU. Do not assume they are included unless the approved model specification and product images show them.

Match the Generator to the Real Load

Confirm running watts, startup demand, voltage, frequency, receptacles, transfer equipment and the exact US configuration before connection.

120V/240V · 60Hz · US
Description
ERAYAK EYG11500iD · US Version

9,500W Max Power9,000W Rated · 120V/240V · 60Hz

An open-frame inverter generator with low-distortion output, electronic speed control and recoil + electric start. Higher-output open-frame inverter power for verified backup, workshop and commercial loads.

9,000WRated power
9,500WMaximum power
120/240VUS output
≤3%THD
4.45 hoursAt 100% load
US Output Configuration

High-Output Inverter Power

Configured for 120V/240V, 60Hz single-phase output. Verify the final US control panel and receptacles before publishing outlet-specific claims.

Core Electrical Performance

Inverter-controlled output combines electronic speed regulation with THD of 3% or lower.

120V/240VUser-confirmed US voltage configuration
60HzUS frequency selection
≤3% THDLow-distortion inverter output
12V / 8.3ADC auxiliary output
PF 1.0Single-phase power factor
LCDStandard voltage display
Fuel Capacity

25L Tank

Large tank capacity supports extended operation and reduces refueling interruptions.

Full-Load Runtime

4.45 hours

Runtime is listed at 100% load under the source-sheet test condition.

Noise Reference

76.9 dB(A)

Noise value is listed at 4 meters and 75% load in the supplied parameter sheet.

Engine & Mobility

Built Around the LY192iD Engine

Electronic speed regulation, ECO operating range and model-specific mobility hardware support transport and load-responsive operation.

459 ccEngine displacement
12kW @ 3800 rpmMaximum engine output
8.8:1Compression ratio
92 × 69 mmBore × stroke
1.1LEngine oil capacity
Recoil + electric startStarting system
3000–3800 rpmECO-mode speed range
8-inch plastic/rubber wheelsMobility configuration
Technical Specifications

EYG11500iD US Configuration

US voltage and frequency follow the user-confirmed configuration; remaining values follow the supplied model parameter sheet.

Power & Operation

  • 9,000W rated / 9,500W maximum output
  • 120V/240V, 60Hz, single-phase
  • THD ≤3%
  • 25L fuel tank
  • 4.45 hours at 100% load
  • 76.9 dB(A) at 4m / 75% load

Control & Transport

  • Inverter voltage regulation
  • Electronic speed control
  • ECO speed: 3000–3800 rpm
  • Standard speed: 3500–3800 rpm
  • 1.6Ah lead-acid battery
  • 8-inch plastic/rubber wheels
Model ERAYAK EYG11500iD · US Version
Generator Type Single-phase open-frame inverter generator
Rated / Maximum Power 9,000W / 9,500W
Voltage / Frequency 120V/240V · 60Hz
Power Factor 1.0
THD ≤3%
DC Output 12V / 8.3A
Fuel Tank 25L
Runtime 4.45 hours at 100% load
Noise 76.9 dB(A) at 4m / 75% load
Engine / Displacement LY192iD / 459 cc
Starting System Recoil + electric start
Oil Capacity 1.1L
Battery 1.6Ah lead-acid battery
Product Dimensions 650 × 542 × 560 mm
Packaging Dimensions 665 × 557 × 605 mm
Net Weight 69 kg
US panel confirmation: NEMA receptacle types, receptacle quantities, breaker ratings, neutral/ground arrangement, fuel configuration, remote-start status, CO shutoff, included accessories, certifications and warranty are not shown for the US configuration in the supplied sheet. Confirm these items before publication.

Generator Safety & Home Backup Reminder

Fuel-burning generators produce carbon monoxide and require correct outdoor placement, electrical connection and refueling practices.

  • Never run indoors.
  • Never run in a garage.
  • Never run near open windows.
  • Always operate outdoors with proper ventilation.
  • Shut down and allow the generator to cool before refueling.
  • Keep the generator dry and do not block cooling or combustion-air openings.
  • Do not connect directly to a building electrical system without code-compliant transfer equipment installed by a qualified professional.
  • Confirm connected loads match 120V/240V, 60Hz output and remain within rated and starting-power limits.
Buyer Questions

EYG11500iD FAQ

Important configuration and load questions to resolve before purchase and installation.

Is this the US electrical version?

This PDP uses the user-confirmed 120V/240V, 60Hz single-phase configuration. Verify the final control panel, labels and receptacles on the approved US production unit.

What is the difference between rated and maximum power?

9,000W is the continuous rated output and 9,500W is the published maximum output. Add simultaneous running loads and account for relevant motor or compressor startup demand.

Does ≤3% THD guarantee compatibility with every electronic device?

No. THD is one power-quality measure. Compatibility also depends on voltage, frequency, startup behavior, grounding, transient response and the connected-equipment manufacturer’s requirements.

How is the runtime measured?

The source sheet lists 4.45 hours at 100% load with a 25L tank. Actual runtime varies with load, operating mode, conditions and the final fuel configuration.

Which NEMA outlets are included?

The supplied sheet does not show the US receptacle layout. Confirm the final NEMA types, quantities, current ratings and breakers before purchase or publication.

Does this model include dual fuel, tri-fuel, remote start or CO shutoff?

The supplied sheet does not confirm these features as standard on the US SKU. Do not assume they are included unless the approved model specification and product images show them.

Match the Generator to the Real Load

Confirm running watts, startup demand, voltage, frequency, receptacles, transfer equipment and the exact US configuration before connection.

120V/240V · 60Hz · US