50L Tank
Large tank capacity supports extended operation and reduces refueling interruptions.







An open-frame inverter generator with low-distortion output, electronic speed control and electric start. Maximum output in this group, with a larger tank and heavy-duty mobility configuration.
Configured for 120V/240V, 60Hz single-phase output. Verify the final US control panel and receptacles before publishing outlet-specific claims.
Inverter-controlled output combines electronic speed regulation with THD of 3% or lower.
Large tank capacity supports extended operation and reduces refueling interruptions.
Runtime is listed at 100% load under the source-sheet test condition.
Noise value is listed at 4 meters and 75% load in the supplied parameter sheet.
Electronic speed regulation, ECO operating range and model-specific mobility hardware support transport and load-responsive operation.
US voltage and frequency follow the user-confirmed configuration; remaining values follow the supplied model parameter sheet.
| Model | ERAYAK EYG15000iD · US Version |
|---|---|
| Generator Type | Single-phase open-frame inverter generator |
| Rated / Maximum Power | 13,000W / 14,000W |
| Voltage / Frequency | 120V/240V · 60Hz |
| Power Factor | 1.0 |
| THD | ≤3% |
| DC Output | 12V / 8.3A |
| Fuel Tank | 50L |
| Runtime | 6.45 hours at 100% load |
| Noise | 76.1 dB(A) at 4m / 75% load |
| Engine / Displacement | LY2V800 / 744 cc |
| Starting System | Electric start |
| Oil Capacity | 1.6L |
| Battery | 36Ah maintenance-free lead-acid battery |
| Product Dimensions | 765 × 625 × 840 mm |
| Packaging Dimensions | 780 × 640 × 865 mm |
| Net Weight | 140 kg |
Fuel-burning generators produce carbon monoxide and require correct outdoor placement, electrical connection and refueling practices.
Important configuration and load questions to resolve before purchase and installation.
This PDP uses the user-confirmed 120V/240V, 60Hz single-phase configuration. Verify the final control panel, labels and receptacles on the approved US production unit.
13,000W is the continuous rated output and 14,000W is the published maximum output. Add simultaneous running loads and account for relevant motor or compressor startup demand.
No. THD is one power-quality measure. Compatibility also depends on voltage, frequency, startup behavior, grounding, transient response and the connected-equipment manufacturer’s requirements.
The source sheet lists 6.45 hours at 100% load with a 50L tank. Actual runtime varies with load, operating mode, conditions and the final fuel configuration.
The supplied sheet does not show the US receptacle layout. Confirm the final NEMA types, quantities, current ratings and breakers before purchase or publication.
The supplied sheet does not confirm these features as standard on the US SKU. Do not assume they are included unless the approved model specification and product images show them.
Confirm running watts, startup demand, voltage, frequency, receptacles, transfer equipment and the exact US configuration before connection.
An open-frame inverter generator with low-distortion output, electronic speed control and electric start. Maximum output in this group, with a larger tank and heavy-duty mobility configuration.
Configured for 120V/240V, 60Hz single-phase output. Verify the final US control panel and receptacles before publishing outlet-specific claims.
Inverter-controlled output combines electronic speed regulation with THD of 3% or lower.
Large tank capacity supports extended operation and reduces refueling interruptions.
Runtime is listed at 100% load under the source-sheet test condition.
Noise value is listed at 4 meters and 75% load in the supplied parameter sheet.
Electronic speed regulation, ECO operating range and model-specific mobility hardware support transport and load-responsive operation.
US voltage and frequency follow the user-confirmed configuration; remaining values follow the supplied model parameter sheet.
| Model | ERAYAK EYG15000iD · US Version |
|---|---|
| Generator Type | Single-phase open-frame inverter generator |
| Rated / Maximum Power | 13,000W / 14,000W |
| Voltage / Frequency | 120V/240V · 60Hz |
| Power Factor | 1.0 |
| THD | ≤3% |
| DC Output | 12V / 8.3A |
| Fuel Tank | 50L |
| Runtime | 6.45 hours at 100% load |
| Noise | 76.1 dB(A) at 4m / 75% load |
| Engine / Displacement | LY2V800 / 744 cc |
| Starting System | Electric start |
| Oil Capacity | 1.6L |
| Battery | 36Ah maintenance-free lead-acid battery |
| Product Dimensions | 765 × 625 × 840 mm |
| Packaging Dimensions | 780 × 640 × 865 mm |
| Net Weight | 140 kg |
Fuel-burning generators produce carbon monoxide and require correct outdoor placement, electrical connection and refueling practices.
Important configuration and load questions to resolve before purchase and installation.
This PDP uses the user-confirmed 120V/240V, 60Hz single-phase configuration. Verify the final control panel, labels and receptacles on the approved US production unit.
13,000W is the continuous rated output and 14,000W is the published maximum output. Add simultaneous running loads and account for relevant motor or compressor startup demand.
No. THD is one power-quality measure. Compatibility also depends on voltage, frequency, startup behavior, grounding, transient response and the connected-equipment manufacturer’s requirements.
The source sheet lists 6.45 hours at 100% load with a 50L tank. Actual runtime varies with load, operating mode, conditions and the final fuel configuration.
The supplied sheet does not show the US receptacle layout. Confirm the final NEMA types, quantities, current ratings and breakers before purchase or publication.
The supplied sheet does not confirm these features as standard on the US SKU. Do not assume they are included unless the approved model specification and product images show them.
Confirm running watts, startup demand, voltage, frequency, receptacles, transfer equipment and the exact US configuration before connection.