ERAYAK 14,000W Max Heavy-Duty Inverter Generator for Large Home Backup, Farms & Demanding Jobsites, 120V/240V

Prix de vente$3,120.00 USD Prix normal$3,170.00 USD
Questions before ordering? Call (573) 455-4565
Description
ERAYAK EYG15000iD · US Version

14,000W Max Power13,000W Rated · 120V/240V · 60Hz

An open-frame inverter generator with low-distortion output, electronic speed control and electric start. Maximum output in this group, with a larger tank and heavy-duty mobility configuration.

13,000WRated power
14,000WMaximum power
120/240VUS output
≤3%THD
6.45 hoursAt 100% load
US Output Configuration

High-Output Inverter Power

Configured for 120V/240V, 60Hz single-phase output. Verify the final US control panel and receptacles before publishing outlet-specific claims.

Core Electrical Performance

Inverter-controlled output combines electronic speed regulation with THD of 3% or lower.

120V/240VUser-confirmed US voltage configuration
60HzUS frequency selection
≤3% THDLow-distortion inverter output
12V / 8.3ADC auxiliary output
PF 1.0Single-phase power factor
LCDStandard voltage display
Fuel Capacity

50L Tank

Large tank capacity supports extended operation and reduces refueling interruptions.

Full-Load Runtime

6.45 hours

Runtime is listed at 100% load under the source-sheet test condition.

Noise Reference

76.1 dB(A)

Noise value is listed at 4 meters and 75% load in the supplied parameter sheet.

Engine & Mobility

Built Around the LY2V800 Engine

Electronic speed regulation, ECO operating range and model-specific mobility hardware support transport and load-responsive operation.

744 ccEngine displacement
18kW @ 3600 rpmMaximum engine output
8.5:1Compression ratio
80 × 74 mmBore × stroke
1.6LEngine oil capacity
Electric startStarting system
2800–3600 rpmECO-mode speed range
10-inch pneumatic wheelsMobility configuration
Technical Specifications

EYG15000iD US Configuration

US voltage and frequency follow the user-confirmed configuration; remaining values follow the supplied model parameter sheet.

Power & Operation

  • 13,000W rated / 14,000W maximum output
  • 120V/240V, 60Hz, single-phase
  • THD ≤3%
  • 50L fuel tank
  • 6.45 hours at 100% load
  • 76.1 dB(A) at 4m / 75% load

Control & Transport

  • Inverter voltage regulation
  • Electronic speed control
  • ECO speed: 2800–3600 rpm
  • Standard speed: 3300–3600 rpm
  • 36Ah maintenance-free lead-acid battery
  • 10-inch pneumatic wheels
Model ERAYAK EYG15000iD · US Version
Generator Type Single-phase open-frame inverter generator
Rated / Maximum Power 13,000W / 14,000W
Voltage / Frequency 120V/240V · 60Hz
Power Factor 1.0
THD ≤3%
DC Output 12V / 8.3A
Fuel Tank 50L
Runtime 6.45 hours at 100% load
Noise 76.1 dB(A) at 4m / 75% load
Engine / Displacement LY2V800 / 744 cc
Starting System Electric start
Oil Capacity 1.6L
Battery 36Ah maintenance-free lead-acid battery
Product Dimensions 765 × 625 × 840 mm
Packaging Dimensions 780 × 640 × 865 mm
Net Weight 140 kg
US panel confirmation: NEMA receptacle types, receptacle quantities, breaker ratings, neutral/ground arrangement, fuel configuration, remote-start status, CO shutoff, included accessories, certifications and warranty are not shown for the US configuration in the supplied sheet. Confirm these items before publication.

Generator Safety & Home Backup Reminder

Fuel-burning generators produce carbon monoxide and require correct outdoor placement, electrical connection and refueling practices.

  • Never run indoors.
  • Never run in a garage.
  • Never run near open windows.
  • Always operate outdoors with proper ventilation.
  • Shut down and allow the generator to cool before refueling.
  • Keep the generator dry and do not block cooling or combustion-air openings.
  • Do not connect directly to a building electrical system without code-compliant transfer equipment installed by a qualified professional.
  • Confirm connected loads match 120V/240V, 60Hz output and remain within rated and starting-power limits.
Buyer Questions

EYG15000iD FAQ

Important configuration and load questions to resolve before purchase and installation.

Is this the US electrical version?

This PDP uses the user-confirmed 120V/240V, 60Hz single-phase configuration. Verify the final control panel, labels and receptacles on the approved US production unit.

What is the difference between rated and maximum power?

13,000W is the continuous rated output and 14,000W is the published maximum output. Add simultaneous running loads and account for relevant motor or compressor startup demand.

Does ≤3% THD guarantee compatibility with every electronic device?

No. THD is one power-quality measure. Compatibility also depends on voltage, frequency, startup behavior, grounding, transient response and the connected-equipment manufacturer’s requirements.

How is the runtime measured?

The source sheet lists 6.45 hours at 100% load with a 50L tank. Actual runtime varies with load, operating mode, conditions and the final fuel configuration.

Which NEMA outlets are included?

The supplied sheet does not show the US receptacle layout. Confirm the final NEMA types, quantities, current ratings and breakers before purchase or publication.

Does this model include dual fuel, tri-fuel, remote start or CO shutoff?

The supplied sheet does not confirm these features as standard on the US SKU. Do not assume they are included unless the approved model specification and product images show them.

Match the Generator to the Real Load

Confirm running watts, startup demand, voltage, frequency, receptacles, transfer equipment and the exact US configuration before connection.

120V/240V · 60Hz · US
Description
ERAYAK EYG15000iD · US Version

14,000W Max Power13,000W Rated · 120V/240V · 60Hz

An open-frame inverter generator with low-distortion output, electronic speed control and electric start. Maximum output in this group, with a larger tank and heavy-duty mobility configuration.

13,000WRated power
14,000WMaximum power
120/240VUS output
≤3%THD
6.45 hoursAt 100% load
US Output Configuration

High-Output Inverter Power

Configured for 120V/240V, 60Hz single-phase output. Verify the final US control panel and receptacles before publishing outlet-specific claims.

Core Electrical Performance

Inverter-controlled output combines electronic speed regulation with THD of 3% or lower.

120V/240VUser-confirmed US voltage configuration
60HzUS frequency selection
≤3% THDLow-distortion inverter output
12V / 8.3ADC auxiliary output
PF 1.0Single-phase power factor
LCDStandard voltage display
Fuel Capacity

50L Tank

Large tank capacity supports extended operation and reduces refueling interruptions.

Full-Load Runtime

6.45 hours

Runtime is listed at 100% load under the source-sheet test condition.

Noise Reference

76.1 dB(A)

Noise value is listed at 4 meters and 75% load in the supplied parameter sheet.

Engine & Mobility

Built Around the LY2V800 Engine

Electronic speed regulation, ECO operating range and model-specific mobility hardware support transport and load-responsive operation.

744 ccEngine displacement
18kW @ 3600 rpmMaximum engine output
8.5:1Compression ratio
80 × 74 mmBore × stroke
1.6LEngine oil capacity
Electric startStarting system
2800–3600 rpmECO-mode speed range
10-inch pneumatic wheelsMobility configuration
Technical Specifications

EYG15000iD US Configuration

US voltage and frequency follow the user-confirmed configuration; remaining values follow the supplied model parameter sheet.

Power & Operation

  • 13,000W rated / 14,000W maximum output
  • 120V/240V, 60Hz, single-phase
  • THD ≤3%
  • 50L fuel tank
  • 6.45 hours at 100% load
  • 76.1 dB(A) at 4m / 75% load

Control & Transport

  • Inverter voltage regulation
  • Electronic speed control
  • ECO speed: 2800–3600 rpm
  • Standard speed: 3300–3600 rpm
  • 36Ah maintenance-free lead-acid battery
  • 10-inch pneumatic wheels
Model ERAYAK EYG15000iD · US Version
Generator Type Single-phase open-frame inverter generator
Rated / Maximum Power 13,000W / 14,000W
Voltage / Frequency 120V/240V · 60Hz
Power Factor 1.0
THD ≤3%
DC Output 12V / 8.3A
Fuel Tank 50L
Runtime 6.45 hours at 100% load
Noise 76.1 dB(A) at 4m / 75% load
Engine / Displacement LY2V800 / 744 cc
Starting System Electric start
Oil Capacity 1.6L
Battery 36Ah maintenance-free lead-acid battery
Product Dimensions 765 × 625 × 840 mm
Packaging Dimensions 780 × 640 × 865 mm
Net Weight 140 kg
US panel confirmation: NEMA receptacle types, receptacle quantities, breaker ratings, neutral/ground arrangement, fuel configuration, remote-start status, CO shutoff, included accessories, certifications and warranty are not shown for the US configuration in the supplied sheet. Confirm these items before publication.

Generator Safety & Home Backup Reminder

Fuel-burning generators produce carbon monoxide and require correct outdoor placement, electrical connection and refueling practices.

  • Never run indoors.
  • Never run in a garage.
  • Never run near open windows.
  • Always operate outdoors with proper ventilation.
  • Shut down and allow the generator to cool before refueling.
  • Keep the generator dry and do not block cooling or combustion-air openings.
  • Do not connect directly to a building electrical system without code-compliant transfer equipment installed by a qualified professional.
  • Confirm connected loads match 120V/240V, 60Hz output and remain within rated and starting-power limits.
Buyer Questions

EYG15000iD FAQ

Important configuration and load questions to resolve before purchase and installation.

Is this the US electrical version?

This PDP uses the user-confirmed 120V/240V, 60Hz single-phase configuration. Verify the final control panel, labels and receptacles on the approved US production unit.

What is the difference between rated and maximum power?

13,000W is the continuous rated output and 14,000W is the published maximum output. Add simultaneous running loads and account for relevant motor or compressor startup demand.

Does ≤3% THD guarantee compatibility with every electronic device?

No. THD is one power-quality measure. Compatibility also depends on voltage, frequency, startup behavior, grounding, transient response and the connected-equipment manufacturer’s requirements.

How is the runtime measured?

The source sheet lists 6.45 hours at 100% load with a 50L tank. Actual runtime varies with load, operating mode, conditions and the final fuel configuration.

Which NEMA outlets are included?

The supplied sheet does not show the US receptacle layout. Confirm the final NEMA types, quantities, current ratings and breakers before purchase or publication.

Does this model include dual fuel, tri-fuel, remote start or CO shutoff?

The supplied sheet does not confirm these features as standard on the US SKU. Do not assume they are included unless the approved model specification and product images show them.

Match the Generator to the Real Load

Confirm running watts, startup demand, voltage, frequency, receptacles, transfer equipment and the exact US configuration before connection.

120V/240V · 60Hz · US